Asset Monitoring

Status-DP – Differential Pressure Sensor

enLink Status-DP measures differential pressure in the range of 25Pa to 5000Pa with industry leading accuracy of 0.1%.

Product Code: ENL-STS-DP

enLink Status-DP measures differential pressure in the range of 25Pa to 5000Pa with industry leading accuracy of 0.1%, ensuring building managers are quickly alerted to system malfunctions. It's unique Multi-Range digital sensor has up to 7 calibrated ranges for unrivalled dynamic range, with the benefit that a single Status-DP unit can cover the full pressure requirements of HVAC and other applications.

Differential Pressure data is transmitted to the cloud using long range LoRa wireless where the device data can be displayed and analysed to reveal operational performance and generate alerts. enLink Status-DP uses long range LoRa wireless to measure and send differential pressure readings for up to 16km. Long life battery power enables simple, low cost installation for a variety of applications.

Download Brochure

Based on LoRaWAN
Technology

Our enLink wireless products use a revolutionary wireless technology called LoRaWAN. LoRa and LoraWAN belong to the category of non-cellular LPWAN wireless communication network protocols, operating in the license-free spectrum.

LoRaWAN technology offers phenomenal range and exceptionally low power requirements, supporting large networks for millions of devices. Deep in-building penetration extends 1-2km. Real-time readings from Synetica devices are transmitted to the cloud without the need for repeaters, where data can be visualised and analysed.

Read More

Up to 7 Calibrated Ranges

Up to 7 Calibrated Ranges

Accuracy: 0.1% per range

Accuracy: 0.1% per range

Exceptional Zero Stability

Exceptional Zero Stability

Selectable Bandwidth Filter

Selectable Bandwidth Filter

Integrated 50/60Hz Filter

Integrated 50/60Hz Filter

Range: 25Pa to 5000Pa

Range: 25Pa to 5000Pa

Long Term Stability ±0.1% FSS

Long Term Stability ±0.1% FSS

Temperature Compensated

Temperature Compensated

enLink Status-DP monitor is a vital tool in areas where the need to monitor differential pressure is paramount, such as hospital operating rooms, agri-tech facilities, labatories, industry and pharmaceutical clean rooms and fume hoods. It can also help to reduce energy consumption by monitoring HVAC equipment for errors or system inefficiencies. When fitted together with Synetica's enLink Status AF the combination of both systems allow building managers to accurately and continously measure both air velocity and differential pressure, providing invaluable information for HVAC and critical air flow systems.

Technical Specification

Get In Touch
To Learn More

Interested in learning more about our products and services? From basic enquiries to complex requirements, we're here to help.